- Home >
- nbc protective equipment >
- Carbon Monoxide Escape Mask
Smoke Personal Escape Gas Masks
Model Number: DSA-CO
Overview
A personal respiratory protective device with visor, hood and built-in filter for escape from fire. Protects against smoke and CO (Carbon Monoxide) inhalation. Complies with European Standard EN-403.
Features
- Pocket-size
- Dons within seconds. No adjustment straps
- One size fits all
- Strong, fire-resistant, elastic rubber hood, protects the entire head and seals comfortably at the neck
- Large visor, made of flame-retardant transparent film, allows a wide field of view
- High-efficiency, electrostatic particle filter, with extremely low pressure-drop to allow easy breathing
- A filtration unit containing low pressure electrostatic particle filter, impregnated charcoal cloth layers to absorb toxic gases and catalyst for Carbon Monoxide Oxidation.
- A unique breathing device (patent pending) enables rapid exhalation and improves the physiological conditions for the user, preventing built-up of heat or vapor inside the mask
- Training model available
Technical Data
Hood:
- Special Polychloroprene Latex Compound
- Elongation at break: > 700%
- Tensile strength: > 150 kg/cm²
- Temperature resistant: 200°C
- Fire-resistant to the requirements of NFPA 701
ETFE film – a copolymer of Polytetrafluoroethylene with Ethylene monomer.
- Tensile strength: 50N/mm²
- Elongation at break: 450%
- Tear resistance: 500 N/mm
- Temperature resistance: 150°C
- Flame retardant : UL 94 V-O
- Light transmission: > 95%
A device combining two valves for exhalation and inhalation + a soft mouthpiece, all in one unit.
Filter Assembly:Two canisters containing the following:
- Electrostatic particle filter
- Layers of impregnated activated charcoal cloth
- Catalyst
- Desiccant
General:
Approximate (package) dimensions: 10x12x14 cm.
Approximate (package) weight: 650 gr.
Filter Performance:
| Test Gas | Challenge Concentration (ml/m3) | Flow Rate (Litre/min) | Breakthrough Criteria (EN403) | Breakthrough time (mins) |
|---|---|---|---|---|
| Propenal (Acrolein) | 100 | 30 | > 15 min (at 0.5 ml/m³) | 20 min |
| Hydrogen Chloride(HCI) | 1000 | 30 | > 15 min (at 5 ml/m³) | >15 min |
| Hydrogen Cyanide (HCN) | 400 | 30 | > 15 min (at 10 ml/m³) | >15 min |
| Carbon Monoxide (CO) | 10,000 | 30 | Total amount of CO penetrated during 15 min < 200 ml | 33 ml during 15 min |
| Test | Requirement (EN 403) | Test results |
|---|---|---|
| Particle filter penetration | <6% | < 1.3% |
| Inhalation resistance | < 8 mbar | 3.6 mbar |
| Exhalation resistance | < 3 mbar | 1.1 mbar |
| Particle filter penetration | <6% | < 1.3% |
| C02 content of inhalation air | < 2.0% | < 1.9% |
| Protection factor | > 50 | > 50 |
Contact Us
Photos