Compact Personal Escape Gas Masks
Model Number: DSA-20C
Overview
A personal emergency device for short-term respiratory protection during escape from situations involving hazardous and toxic air. For private homeowners, hotels, high-rises, hospitals, ships and aircraft.
Features
- Pocket-size
- Dons within seconds. No adjustment straps
- One size fits all
- Strong, fire-resistant, elastic rubber hood, protects the entire head and seals comfortably at the neck
- Large visor, made of flame-retardant transparent film, allows a wide field of view
- High-efficiency, electrostatic particle filter, with extremely low pressure-drop to allow easy breathing
- Layers of activated charcoal with special impregnation to absorb toxic gases
- A unique breathing device (patent pending) enables rapid exhalation and improves the physiological conditions for the user, preventing built-up of heat or vapor inside the mask
- Training model available
- Available in two colors: yellow and black
Technical Data
Hood:
- Special Polychloroprene Latex Compound
- Elongation at break: > 700%
- Tensile strength: > 150 kg/cm²
- Temperature resistant: 200°C
- Fire-resistant to the requirements of NFPA 701
ETFE film – a copolymer of Polytetrafluoroethylene with Ethylene monomer.
- Tensile strength: 50N/mm²
- Elongation at break: 450%
- Tear resistance: 500 N/mm
- Temperature resistance: 150°C
- Flame retardant : UL 94 V-O
- Light transmission: > 95%
A device combining two valves for exhalation and inhalation + a soft mouthpiece, all in one unit.
Filter Assembly:Multi-Layer filter includes the following:
- External polyester screen, fire resistant to the requirements of NFPA 701
- Electrostatic particle filter
- Electrostatic + melt blown combination high efficiency particle filter (HEPA)
- Layers of activated charcoal cloth with impregnation against acid gases
- Soft inner pad of non-woven material
General:
Approximate (package) dimensions: 19x15x2 cm.
Approximate (package) weight: 150 gr.
Filter Performance:
| Test Gas | Challenge Concentration (ppm) | Flow Rate (Litre/min) | Time to Breakthrough |
|---|---|---|---|
| Hydrogen Chloride (HCI) | 1000 | 20 | 60 min at 5 ppm |
| Hydrogen Cyanide (HCN) | 400 | 20 | > 40 min at 1 ppm |
| Nitrogen Dioxide (N02) | 200 | 20 | > 25 min at 5 ppm |
| Sulfur Dioxide (S02) | 150 | 20 | 25 min at 5 ppm |
Particle Penetration: Meets EN 143 P2.
Pressure drop at 20 lit/min: 0.06 mbar